Wednesday, August 03, 2011

The $1bn contract to connect North Sea windfarms

BorWin Alpha wind farm in the North Sea
What is possibly the world's largest ever order - at $1bn - for grid connection technology for offshore wind farms has been signed, an indicator of the coming huge expansion in wind capacity in Europe.

Dutch-German transmission grid operator TenneT has commissioned ABB, a power and automation technology group, to supply a power link connecting offshore North Sea wind farms to the German mainland grid.

The initiative will form part of Germany's plans to meet its carbon reduction targets while phasing out its nuclear power plants.

When completed, it will be the world’s largest offshore HVDC (high-voltage direct current) system - rated at over 900 megawatts (MW) - and will be capable of supplying over 1.5 million households with wind-generated electricity.

It will utilise ABB's HVDC (high voltage direct current) Light technology. This means that by transmitting the power at high voltage in direct current (DC), rather than alternating current (AC), electrical losses over distance can be kept to below 1% per converter station.

The technology is well proven and ten years old - ABB has previously used it to connect the BorWin1 windfarm and last year won a contract to connect the 800MW Dolwin1 windfarm, both also in the North Sea.
Map of DolWin windfarm in the North Sea
The cables can transmit power underground and underwater over long distances with the other advantages of having neutral electromagnetic fields, oil-free cables and compact converter stations.

The company claims that it is economically feasible to expand transmission capacity using this system, to minimise the visual and environmental impact of the grid and improve the quality of the power supply.

The expense and visual intrusion of overland grid-connection cables has become a focus for opposition to the expansion of wind power in the UK , particularly in Scotland.

The planned connector will link the 400 MW Gode Wind II and other wind farms in the North Sea, sending DC electricity at 320 kilovolts to a converter station at Dörpen on the German coast, via another station offshore, along 135 kilometers of underwater and underground cables. It will then feed AC electricity into the mainland grid.

It should be completed by 2015, so that by 2020 Germany will have more than doubled its offshore wind electricity generation, from its present 8% of total supply (a capacity of over 27 gigawatts).

Britain and Germany are both competitors and partners in the race to establish windfarms in the North Sea. Wind energy is expected to more than triple its power output by 2020 in the EU.

Energy and Climate Change Minister Chris Huhne, on a visit yesterday to the Vestas wind turbine facility in the Isle of Wight, spoke enthusiastically of the UK leading the world in the area, with some 1.5GW of wind capacity installed.

"Last week’s new European Wind Energy Association numbers found almost all turbines installed in the first half of this year were in the UK: 101 off the UK, compared to just 7 in the rest of Europe," he said.

Justin Wilkes, Policy Director of the European Wind Energy Association (EWEA), believes that 194 billion Euros will be invested in European onshore and offshore wind farms in this decade. "This success is mainly driven by a strong EU regulatory framework to 2020, which we need also after 2020," he said, as he launched a new EWEA report on scenarios for onshore and offshore wind power deployment in the EU.

This says that electricity production from wind power is expected to increase from 182 Terawatt hours (TWh) or 5.5% of the total EU demand in 2010, to 581 TWh or 15.7% of the total demand in 2020. At this point it will be equivalent to the combined electricity consumption of all households in France, Germany, Poland, Spain and the United Kingdom.

Chris Huhne would like to see many more of the turbines that are erected around the UK being built in this country, which was a motivation for his visit to the Vestas facility in Newport on the Isle of Wight. This was a turbine-making factory that Vestas closed two years ago despite attempts by the government to dissuade its Danish owner.

Huhne said that he believes "Vestas are one of a number of companies who have announced intentions to open turbine manufacturing plants in the UK. I very much hope to see that intention become reality.”

Despite not making wind turbines, the factory still employs 220 people. It is testimony to efforts by islanders to attain its council's goal of being carbon neutral by 2020.

Huhne saw how the facility now designs and tests wind turbine blades. “Innovative new components, including those likely to be tested and developed here in these very facilities, will play a crucial role in bringing [future wind power] costs down," Huhne said. "As will new, high yield, multi-megawatt turbines of the type Vestas have recently announced."

Council representatives and members of the Eco Island community group then discussed with Chris Huhne proposals to create an ocean energy centre to test tidal and wave technology off the west and south coasts of the island.

Thursday, March 18, 2010

Grid connection and intermittency of renewable energy

It's still said that when the wind doesn't blow you need other sources of power, so wind farms are really a waste of money.

This topic - grid integration of renewables and variability - has been extensively investigated.

One conclusion - from the UK Government report quoted below - is: "For penetrations of intermittent renewables up to 20% of electricity supply, additional system balancing reserves due to short term (hourly) fluctuations in wind generation amount to about 5-10% of installed wind capacity."

Peter Freere, formerly an engineering professor at Monash University in Australia says:

"It is correct that in normal electric grids (without energy storage - eg pumped storage, charging electric cars, etc.), a single wind farm would not work well on its own and some conventional energy sources are also required.

"The same applies to the conventional energy sources, especially nuclear, whose response time is so slow that they must have a fast responding generation system in parallel.

"It is also true that due to the large sizes of modern generators in conventional systems (eg. 500 MW per generator), to allow for maintenance and breakdowns, it is necessary to have a complete spare generator ready to take over when another stops working (for whatever reason)."

"Hence the risk with wind farms is not so great - no more than many conventional systems."

The largest study on grid integration was done in Germany by DENA. The gist is that investment in the grid will be necessary to integrate the new renewable generation needed meet the German target of 20% of supply from renewable energy by 2020. The investment required is less expensive than additional grid expansion if new central-station plants are built, and this investment will result in making the grid more stable with or without the renewable generation.

A March 2006 UK Energy Research Centre report analysed the results of 200 studies on the grid integration of intermittent renewables. The following are excerpts from the summary of The Costs and Impacts of Intermittency: An assessment of the evidence on the costs and impacts of intermittent generation on the British electricity network. Below are its conclusions:

  • It is sometimes said that wind energy, for example, does not reduce carbon dioxide emissions because the intermittent nature of its output means it needs to be backed up by fossil fuel plant. Wind turbines do not displace fossil generating capacity on a one-for-one basis. But it is unambiguously the case that wind energy can displace fossil fuel-based generation, reducing both fuel use and carbon dioxide emissions.

  • Wind generation does mean that the output of fossil fuel-plant needs to be adjusted more frequently, to cope with fluctuations in output. Some power stations will be operated below their maximum output to facilitate this, and extra system balancing reserves will be needed. Efficiency may be reduced as a result. At high penetrations (above 20%) energy may need to be 'spilled' because the electricity system cannot always make use of it. (However it is hoped that in the future elecric cars will be charged sing this energy.) But overall these effects are much smaller than the savings in fuel and emissions that renewables can deliver at the levels of penetration examined in this report.

  • None of the 200+ studies reviewed suggest that introducing significant levels of intermittent renewable energy generation on to the British electricity system must lead to reduced reliability of electricity supply2. Many of the studies consider intermittent generation of up to 20% of electricity demand, some considerably more. It is clear that intermittent generation need not compromise electricity system reliability at any level of penetration foreseeable in Britain over the next 20 years, although it may increase costs. In the longer term much larger penetrations may also be feasible given appropriate changes to electricity networks.

  • The introduction of significant amounts of intermittent generation will affect the way the electricity system operates. There are two main categories of impact and associated cost. The first, so called system balancing impacts, relates to the relatively rapid short term adjustments needed to manage fluctuations over the time period from minutes to hours. The second, which is termed here 'reliability impacts', relates to the extent to which we can be confident that sufficient generation will be available to meet peak demands. No electricity system can be 100% reliable, since there will always be a small chance of major failures in power stations or transmission lines when demands are high. Intermittent generation introduces additional uncertainties, and the effect of these can be quantified.

  • System balancing entails costs which are passed on to electricity consumers. Intermittent generation adds to these costs. For penetrations of intermittent renewables up to 20% of electricity supply, additional system balancing reserves due to short term (hourly) fluctuations in wind generation amount to about
    5-10% of installed wind capacity. Globally, most studies estimate that the associated costs are less than £5/MWh ($0.0087/kWh) of intermittent output, in some cases substantially less. The range in UK relevant studies is £2 - £3/MWh ($0.0035-$0.0052/kWh).

  • Unless there is a large amount of responsive or controllable demand, a system margin is needed to cope with unavailability of installed generation and fluctuations in electricity requirements (e.g. due to the weather). Conventional plant - coal, gas, nuclear - cannot be completely relied upon to generate electricity at times of peak demand as there is, very approximately, a one-in-ten chance that unexpected failures (or "forced outages") in power plant or electricity transmission networks will cause any individualconventional generating unit not to be available to generate power. Even with a system margin, there is no absolute guarantee in any electricity system that all demands can be met at all times.

  • Intermittent generation increases the size of the system margin required to maintain a given level of reliability. This is because the variability in output of intermittent generators means they are less likely to be generating at full power at times of peak demand. The system margin needed to achieve a desired level of reliability depends on many complex factors but may be explored by statistical calculations or simplified models. Intermittent generation introduces new factors into the calculations and changes some of the numbers, but it does not change the fundamental principles on which such calculations are based.

  • Intermittent generators can make a contribution to system reliability, provided there is some probability of output during peak periods. They may be generating power when conventional stations experience forced outages and their output may be independent of fluctuations in energy demand. These factors can be taken into account when the relationship between system margin and reliability is calculated using statistical principles.

  • Capacity credit is a measure of the contribution that intermittent generation can make to reliability. It is usually expressed as a percentage of the installed capacity of the intermittent generators. There is a range of estimates for capacity credits in the literature and the reasons for there being a range are well understood. The range of findings relevant to British conditions is approximately 20 - 30% of installed capacity when up to 20% of electricity is sourced from intermittent supplies (usually assumed to be wind power). Capacity credit as a percentage of installed intermittent capacity declines as the share of electricity supplied by intermittent sources increases.

  • The capacity credit for intermittent generation, the additional conventional capacity required to maintain a given level of reliability and thus the overall system margin are all related to each other. The smaller the capacity credit, the more capacity needed to maintain reliability, hence the larger the system margin. The amount by which the system margin must rise in order to maintain reliability has been described in some studies as "standby capacity","back-up capacity" or the "system reserves". But there is no need to provide dedicated "back-up" capacity to support individual generators. [Emphasis added] These terms have meaning only at the system level.

  • This assumes around 20% of electricity is supplied by well dispersed wind power. Current costs are much lower; indeed there is little or no impact on reliability at existing levels of wind power penetration. The cost of maintaining reliability will increase as the market share of intermittent generation rises.

  • The aggregate 'costs of intermittency' are made up of additional short-run balancing costs and the additional longer term costs associated with maintaining reliability via an adequate system margin. Intermittency costs in Britain are of the order of £5 to £8/MWh ($0.0087-$0.0139/kWh), made up of £2 to £3/MWh from shortrun balancing costs and £3 to £5/MWh from the cost of maintaining a higher system margin. For comparison, the direct costs of wind generation would typically be approximately £30 to £55/MWh ($0.052-$0.0958). If shared between all consumers the impact of intermittency on electricity prices would be of the order 0.1to 0.15 p/kWh ($0.0017-$0.0026/kWh).


Below are a few links to other reports on grid integration of renewables.